Industrial robots, collaborative robots, humanoid robots, and medical robots rely on tightly integrated joint systems. A typical robotic joint may contain a permanent magnet motor, gearbox, position encoder, torque sensor, brake, bearing, power electronics, and controller.

Magnetic field components are used not only to generate motor torque but also to measure position, speed, current, torque, and proximity. High robot performance therefore depends on how effectively the motor magnetic circuit, capteurs magnétiques, mechanical transmission, and control algorithm work together.

je. What Magnetic Components Are Used in Robots?

Magnetic ComponentMain FunctionCommon Paired Component
Rotor permanent magnetsInteract with the stator field to produce torqueBrushless DC or permanent magnet synchronous motor
Encoder magnet or magnetic ringProvides angular position and speed informationSalle, AMR, GMR, or TMR sensor
Current-sensing magnetic coreConcentrates the magnetic field generated by phase currentHall-effect or magnetoresistive sensor
Magnetic brake assemblyHolds the joint after power is removedElectromagnetic brake
Magnetoelastic torque structureConverts mechanical stress into a measurable magnetic changeMagnetic or magnetoresistive sensor
Flux guide and magnetic shieldControls leakage flux and field distributionSoft magnetic alloy, pure iron, or ferrite

These components cannot be designed independently. Leakage flux from the motor may enter the encoder area, while inverter current and power cables may create additional alternating magnetic fields around sensitive sensors.

II. How Do Motors and Sensors Form a Control Loop?

A robotic joint generally uses several nested feedback loops. The current loop is the fastest and regulates electromagnetic torque. The speed loop uses encoder information to control rotational velocity, while the position loop compares the commanded and actual joint angles.

Torque sensors or output-shaft encoders may provide additional feedback about gearbox deformation, backlash, external force, or contact with the environment.

High-precision joints often include one encoder at the motor rotor and another at the output shaft. The motor-side encoder supports commutation and fast motor control. The output encoder measures the actual joint position after the gearbox and can reveal transmission error, torsional deformation, and backlash.

Feedback SignalMain Control FunctionTypical Design Requirement
Phase currentElectromagnetic torque controlHigh bandwidth and low offset
Rotor positionMotor commutationAccurate electrical angle
Rotor speedDynamic speed regulationLow noise and short delay
Output angleTrue joint position controlHigh resolution and good repeatability
Joint torqueForce and compliance controlLow drift and overload resistance
TempératureThermal protection and compensationCorrect placement and fast response

III. What Problems Can Magnetic Interference Cause?

1. Encoder Angle Error

Magnetic encoders calculate angle from field direction or field components. Misalignment, changing air gaps, magnet eccentricity, and motor leakage flux can create offset, nonlinearity, and periodic angle error.

Even when an encoder has high nominal resolution, installation error may limit the true system accuracy.

2. Current and Torque Estimation Error

External magnetic fields, core remanence, temperature drift, and conductor position can shift the zero point of magnetic current sensors.

Because motor torque is often calculated from phase current, a current measurement error can directly become a torque-control error.

3. Local Magnetic Saturation

Flux guides and shielding parts must have sufficient cross-sectional area and saturation capability. If a local region saturates, magnetic flux no longer increases linearly with current.

Saturation may reduce motor torque, distort sensor signals, increase harmonics, and cause unexpected heating.

4. Temperature-Related Drift

Permanent magnet flux, winding resistance, Hall sensitivity, magnetic sensor gain, and soft magnetic permeability all change with temperature.

If temperature effects are ignored, a joint calibrated at room temperature may produce errors after continuous high-load operation.

IV. How Can Motors and Magnetic Sensors Be Efficiently Coordinated?

1. Conduct Joint Electromagnetic Simulation

Motor simulation should evaluate more than torque, efficacité, and back electromotive force. Designers should also calculate leakage fields around encoders, brakes, current sensors, and signal wiring.

Electromagnetic analysis can be combined with thermal, structural, and control models. This helps determine whether sensor errors will increase when the motor becomes hot, the shaft deflects, or the bearing air gap changes.

2. Optimize Magnet and Sensor Placement

The encoder magnet should be accurately centered on the rotating shaft, and the sensor air gap should remain within its specified range.

Where motor leakage is strong, designers can increase separation, add a flux return path, use differential sensing, or install a magnetic shield. Shielding thickness should be calculated because a saturated shield may lose effectiveness.

3. Synchronize Signal Acquisition

Current, position, speed, torque, and temperature data should be sampled with consistent timing. Unsynchronized measurements force the controller to combine states from different moments, reducing dynamic accuracy.

Precise time stamping and deterministic communication are especially important in multi-axis robots.

4. Calibrate the Complete Joint

A motor and encoder may each meet their individual specifications, yet the assembled joint may still show significant error.

Complete joint calibration should include mechanical zero, magnetic offset, eccentricity compensation, torque constant, friction, gearbox transmission error, and temperature drift.

5. Use Sensor Fusion

Combining motor current, dual encoder data, torque sensing, inertial measurement, and temperature information allows the controller to distinguish between actual load changes and sensor errors.

Sensor fusion can also improve fault detection. Par exemple, a disagreement between motor current and measured joint torque may indicate gearbox damage, mechanical blockage, or calibration drift.

V. How Should Magnetic Materials Be Selected?

Rotor magnets should be selected according to torque density, operating temperature, reverse-field resistance, coût, and corrosion conditions. Neodymium-iron-boron provides high magnetic energy, samarium-cobalt offers strong high-temperature stability, and ferrite can be suitable for cost-sensitive designs with sufficient space.

Electrical steel, soft magnetic composites, pure iron, or high-permeability alloys may be used for stators, flux guides, shields, and sensor structures.

A higher-grade magnet does not automatically improve the complete robot. Stronger magnets may increase leakage flux, sensor interference, mechanical attraction, et le coût. Material selection must be coordinated with magnetic circuit geometry and control requirements.

Conclusion

Efficient cooperation between robotic magnetic components, moteurs, and sensors requires a complete chain from magnetic field generation and mechanical output to state measurement and closed-loop control.

Joint simulation, controlled leakage flux, accurate sensor placement, synchronized sampling, dual-encoder feedback, temperature compensation, and complete-system calibration can reduce angle error and torque ripple.

Le best robotic joint is not simply the one with the strongest magnet or highest-resolution sensor. It is the one in which magnetic, mechanical, electronic, and control components are designed as one coordinated system.